SM33-6-50VDC2

Circuit Breakers

CIRCUIT BREAKER

SM33-6-50VDC2

5925-00-548-1364

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.562 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    4 wire hook

  • Body Style

    multipole-single actuator type

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct

  • Test Data Document

    81349-mil-c-39019 specification

  • Specification/Standard Data

    81349-mil-c-39019/3 government specification

  • Body Width

    1.281 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...