230624

Switches

SWITCH,ROTARY

230624

5930-00-548-8532

5930 - Switches

L-3 Communications Corporation

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Shaft Type

    round, flatted single actuator

  • Nonturn Device Radius

    0.500 inches minimum at 12:00 o'clock and 0.562 inches maximum at 12:00 o'clock

  • Contact Switching Action

    makes before breaks single section rear

  • Mounting Method

    threaded bushing single mounting facility

  • Overall Width

    1.531 inches minimum and 1.593 inches maximum

  • Thread Class

    2a single mounting facility

  • Terminal Type

    tab, solder lug

  • Flat Height

    0.187 inches minimum single actuator and 0.249 inches maximum single actuator

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.250 inches maximum single actuator

  • Individual Section Quantity

    1

  • Contact Load Current Rating

    0.5 amperes resistive load ac at sea level

  • Contact Load Current Rating

    0.1 amperes resistive load dc at sea level

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Throw Quantity

    3 single section rear

  • Switch Actuator Indexing Position Quantity

    3 single actuator

  • Pole Quantity

    3 single section rear

  • Shaft Flat/Slot Angular Location

    135.0 degrees from nonturn device single actuator

  • Overall Length

    1.625 inches minimum and 1.718 inches maximum

  • First Flat Length

    0.281 inches minimum single actuator and 0.343 inches maximum single actuator

  • Style Designator

    circular wafer, bushing mount

  • Overall Height

    1.844 inches minimum and 1.906 inches maximum

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Shaft Length

    0.844 inches minimum single actuator and 0.906 inches maximum single actuator

  • Nonturn Device Type

    pin at 12:00 o'clock

  • Err Default

    err default and err default

  • Contact Voltage Rating In Volts

    115.0 dc at sea level

  • Nominal Thread Size

    0.375 inches single mounting facility

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.