S0012132SA
Relays and Solenoids
RELAY,ELECTROMAGNETIC
S0012132SA
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Maximum Voltage Rating In Volts
32.0 dc
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
9.562 inches nominal single mounting facility
-
Nonpile-Up Main Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Mounting Facility Pattern
isosceles triangle single mounting facility
-
Duty Type
intermittent
-
Winding Dc Resistance Rating
700.0 ohms nominal single winding
-
Coil Quantity
1
-
Winding Quantity
1
-
Environmental Protection
dustproof
-
Overall Length
10.500 inches nominal
-
Terminal Type And Quantity
4 pin all functions
-
Special Features
magnetic contact opener incl
-
Main Contact Load Current Rating At Maximum Rated Voltage
10000.0 amperes dc resistive load
-
Operating Voltage Rating And Type At Specified Temp
32.0 volts dc 25 deg celsius single winding
-
Nominal Operating Current Rating And Type
14.3 amperes dc single winding
-
Mounting Facility Type And Quantity
3 unthreaded hole single mounting facility
-
Arc Quenching Method
magnetic
-
Unthreaded Mounting Hole Diameter
0.344 inches nominal single mounting facility
-
Overall Height
5.370 inches nominal