GA52694

Filters and Networks

FILTER,BAND PASS

GA52694

5915-00-552-0882

5915 - Filters and Networks

Lucent Technologies Inc

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specified Frequencies Of Discrimination Per Function

    1.90 kilohertz 1st band pass and 600.00 hertz 1st band pass and 1.10 kilohertz 1st band pass and 2.40 kilohertz 1st band pass

  • Output Impedance Per Function W/Source Across Input

    2.0 kilohms 1st band pass

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.164 inches

  • Input Impedance Per Function W/Load

    20.0 kilohms 2nd band pass

  • Body Width

    2.625 inches nominal

  • Output Impedance Per Function W/Source Across Input

    2.0 kilohms 2nd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.250 inches nominal

  • Overall Height

    6.062 inches nominal

  • Reference Frequency Per Function

    1.5 single radio interference pulses per second

  • Body Length

    4.750 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Functional Terminal Type And Quantity

    6 wire lead output 2nd function

  • Frequency Band Width Per Function

    500.00 hertz 2nd band pass and 700.00 hertz 2nd band pass

  • Frequency Band Width Per Function

    1.10 kilohertz 1st band pass and 1.90 kilohertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 1st band pass and 40.0 minimum 1st band pass and 1.0 maximum 1st band pass and 40.0 minimum 1st band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Vibration Resistance Range In Hertz

    +10.0/+55.0

  • Functional Terminal Type And Quantity

    2 wire lead input 1st function

  • Input Impedance Per Function W/Load

    20.0 kilohms 1st band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Inclosure Type

    encased

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 1st band pass

  • Operating Temp Range

    +0.0/+52.0 deg celsius

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 maximum 2nd band pass and 1.0 maximum 2nd band pass and 40.0 minimum 2nd band pass and 40.0 minimum 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    700.00 hertz 2nd band pass and 500.00 hertz 2nd band pass and 100.00 hertz 2nd band pass and 1.50 kilohertz 2nd band pass

  • Reference Frequency Per Function

    600.0 single high pass two phase to two phase

  • Body Surface Treatment

    tin

  • Insertion Loss At Reference Frequency Per Function In Decibels

    1.0 2nd band pass

  • Body Height

    5.312 inches nominal

  • Body Material

    metal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...