GA52694
Filters and Networks
FILTER,BAND PASS
GA52694
American Telephone And Telegraph Co
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Specified Frequencies Of Discrimination Per Function
1.90 kilohertz 1st band pass and 600.00 hertz 1st band pass and 1.10 kilohertz 1st band pass and 2.40 kilohertz 1st band pass
-
Output Impedance Per Function W/Source Across Input
2.0 kilohms 1st band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.164 inches
-
Input Impedance Per Function W/Load
20.0 kilohms 2nd band pass
-
Body Width
2.625 inches nominal
-
Output Impedance Per Function W/Source Across Input
2.0 kilohms 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.250 inches nominal
-
Overall Height
6.062 inches nominal
-
Reference Frequency Per Function
1.5 single radio interference pulses per second
-
Body Length
4.750 inches nominal
-
Mounting Facility Type And Quantity
4 threaded stud
-
Functional Terminal Type And Quantity
6 wire lead output 2nd function
-
Frequency Band Width Per Function
500.00 hertz 2nd band pass and 700.00 hertz 2nd band pass
-
Frequency Band Width Per Function
1.10 kilohertz 1st band pass and 1.90 kilohertz 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.0 maximum 1st band pass and 40.0 minimum 1st band pass and 1.0 maximum 1st band pass and 40.0 minimum 1st band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Functional Terminal Type And Quantity
2 wire lead input 1st function
-
Input Impedance Per Function W/Load
20.0 kilohms 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Inclosure Type
encased
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 1st band pass
-
Operating Temp Range
+0.0/+52.0 deg celsius
-
Discrimination At Specified Frequencies Per Function In Decibels
1.0 maximum 2nd band pass and 1.0 maximum 2nd band pass and 40.0 minimum 2nd band pass and 40.0 minimum 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
700.00 hertz 2nd band pass and 500.00 hertz 2nd band pass and 100.00 hertz 2nd band pass and 1.50 kilohertz 2nd band pass
-
Reference Frequency Per Function
600.0 single high pass two phase to two phase
-
Body Surface Treatment
tin
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.0 2nd band pass
-
Body Height
5.312 inches nominal
-
Body Material