PEI 1999
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
PEI 1999
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Primary To Secondary Turn Ratio
1 to 44 single component
-
Winding Shielding Method
internal shield grounded to inclosure and core and brought out to terminal single component
-
Terminal Type And Quantity
9 tab, solder lug
-
Body Length
2.188 inches nominal
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Frequency Rating
400.0 hertz maximum single component
-
Transformer Function
input
-
Impedance Rating In Ohms
1500.0 nominal single component single primary
-
Body Outside Diameter
1.562 inches nominal
-
Reliability Indicator
not established
-
Winding Tap Location (Non-Core)
center tap single component all secondary
-
Inclosure Type
hermetically sealed
-
Impedance Rating In Ohms
726000.0 nominal single component all secondary
-
Special Features
secondary electrostatic shields connected internally to secondaries center taps