AM13MG6-0.75-115-5-60

Circuit Breakers

CIRCUIT BREAKER

AM13MG6-0.75-115-5-60

5925-00-552-3429

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes ac single location

  • Actuator Function

    trip-reset

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.380 minimum at 200 pct single location and 1.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Length

    2.500 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...