2263SM6-60-125

Circuit Breakers

CIRCUIT BREAKER

2263SM6-60-125

5925-00-552-5440

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    9b multipole-single actuator type

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Body Width

    1.990 inches minimum and 2.010 inches maximum

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.164 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct and 105.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    4 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.990 inches minimum and 1.010 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...