2131644-3

Circuit Breakers

CIRCUIT BREAKER

2131644-3

5925-00-558-4242

5925 - Circuit Breakers

Honeywell Intl Inc Defense Avionics

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.190 inches

  • Body Length

    2.500 inches nominal

  • Actuator Position Designation

    at each pole

  • Switch Location And Position Designation

    internal at pole one

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Case Material

    plastic

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Width

    2.250 inches nominal

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Mounting Surface To Terminal End Distance

    2.640 inches nominal

  • Pole Quantity

    3

  • Boss Height

    0.150 inches nominal

  • Auxiliary Switch Function And Quantity

    2 control

  • Internal Trip Release Configuration

    series trip all locations

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Terminal Type

    quick disconnect, male

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Thread Series Designator

    unf

  • Frequency In Hertz

    400.0 all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...