M430055-8REV9

Circuit Breakers

CIRCUIT BREAKER

M430055-8REV9

5925-00-568-9871

5925 - Circuit Breakers

Rca Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location and 30.0 dc single location

  • Pole Quantity

    1

  • Nominal Thread Size

    0.468 inches

  • Mounting Surface To Terminal End Distance

    1.344 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.031 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 ac single location and 575.0 dc single location

  • Bushing Length

    0.250 inches nominal

  • Fragility Factor

    moderately rugged

  • Actuator Function

    reset

  • Thread Quantity Per Inch

    32

  • Terminal Type And Quantity

    2 screw

  • Manual Actuator Type And Quantity

    1 push button

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Length

    1.312 inches nominal

  • Body Width

    0.703 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    weatherproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...