45-700-P10 10 AMP

Circuit Breakers

CIRCUIT BREAKER

45-700-P10 10 AMP

5925-00-572-4999

5925 - Circuit Breakers

Getronics Government Solutions Llc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Bushing Length

    0.313 inches minimum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    27

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Unpackaged Unit Weight

    1.000 ounces

  • Nominal Thread Size

    0.375 inches

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location and 24.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.634 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Body Width

    0.694 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 240.0 dc single location

  • Body Length

    1.387 inches maximum

  • Mounting Surface To Terminal End Distance

    2.281 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...