352250009223
Circuit Breakers
CIRCUIT BREAKER
352250009223
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Terminal Type
tab, solder lug
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.950 maximum at 200 pct all locations and 0.055 minimum at 200 pct all locations and 0.130 maximum at 600 pct all locations and 0.240 maximum at 400 pct all locations and 0.060 maximum at 800 pct all locations
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Switch Location And Position Designation
internal at pole two
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Terminal Type And Quantity
4 wire hook
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Ultimate Trip Time Per Pole In Seconds
0.200 minimum all locations and 7.000 maximum all locations
-
Thread Series Designator
unef
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes dc all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Width
1.281 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Bushing Length
0.380 inches maximum
-
~1
data on certain environmental and performanc
-
Test Data Document