D6761-1-10

Circuit Breakers

CIRCUIT BREAKER

D6761-1-10

5925-00-573-4365

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches nominal

  • Mounting Facility Type And Quantity

    thd bushing

  • Terminal Type And Quantity

    2 screw

  • Mounting Surface To Terminal End Distance

    2.188 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Length

    1.094 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.468 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    100.000 maximum at 200 pct single location and 3.000 minimum at 400 pct single location and 40.000 minimum at 200 pct single location and 11.000 maximum at 400 pct single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.469 inches nominal

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Width

    0.750 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 4000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...