PDA-5
Circuit Breakers
CIRCUIT BREAKER
PDA-5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Internal Trip Release Configuration
series trip single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Trip Release Characteristic
time delay single location
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
-
Overall Length
2.000 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Reset Method
automatic
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.781 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
-
Mounting Surface To Terminal End Distance
1.312 inches nominal
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum single location
-
Storage Type
general purpose warehouse
-
Body Width
1.250 inches nominal
-
Terminal Type And Quantity
2 screw