PCB730AM1515-15MG3CURVE2

Circuit Breakers

CIRCUIT BREAKER

PCB730AM1515-15MG3CURVE2

5925-00-577-2897

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Overall Length

    3.719 inches nominal

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Body Width

    0.980 inches minimum and 1.000 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Overall Height

    4.141 inches nominal

  • Overall Width

    0.990 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Mounting Surface To Terminal End Distance

    3.229 inches minimum and 3.249 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct single location and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof

  • Special Features

    single throws,copper and brass main contacts and back connected terminals

  • Frequency In Hertz

    60.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...