9504-32

Circuit Breakers

CIRCUIT BREAKER

9504-32

5925-00-581-0393

5925 - Circuit Breakers

Beseler Charles Co Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct single location and 100.500 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 bus bar

  • Body Style

    single pole type

  • Body Height

    2.830 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    4.380 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Unpackaged Unit Weight

    0.688 pounds

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Body Length

    4.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Body Width

    1.030 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...