9155616

Circuit Breakers

CIRCUIT BREAKER

9155616

5925-00-581-7236

5925 - Circuit Breakers

U S Army Aviation And Missile

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    8.219 inches minimum and 8.281 inches maximum

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    20.719 inches minimum and 20.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.344 inches minimum and 1.406 inches maximum

  • Boss Height

    0.219 inches minimum and 0.281 inches maximum

  • Mounting Surface To Terminal End Distance

    9.969 inches minimum and 10.031 inches maximum

  • Mounting Facility Type And Quantity

    8 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    thermal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Actuator Position Designation

    at pole two

  • Adjustable Trip Setting Current Range Per Pole In Amps

    p500.0/p1500.0 ac

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1000.000 nominal at 125 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    21.969 inches minimum and 22.031 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    17.469 inches minimum and 17.531 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    2.719 inches minimum and 2.781 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and 28.0 dc

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    65.0 deg celsius maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...