APL1R-77819

Circuit Breakers

CIRCUIT BREAKER

APL1R-77819

5925-00-583-5944

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.790 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Trip Release Method

    magnetic

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Body Style

    single pole type

  • Body Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Boss Height

    0.125 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Circuit Protection Type

    overcurrent

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...