D6760-1-5

Circuit Breakers

CIRCUIT BREAKER

D6760-1-5

5925-00-583-7613

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Body Width

    2.203 inches maximum

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    tamperproof and shockproof and fungus resistant

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.486 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    0.743 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    220.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Body Height

    2.125 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    2.250 inches maximum

  • Unpackaged Unit Weight

    3.000 ounces

  • Terminal Type And Quantity

    6 tab w/screw

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...