Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Location And Position Designation

    internal at pole three

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct all locations and 1.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Unpackaged Unit Weight

    14.000 ounces

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Nominal Thread Size

    0.138 inches

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.533 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Body Style

    8c multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...