44-100P50-3
Circuit Breakers
CIRCUIT BREAKER
44-100P50-3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Position Designation
at pole one
-
Mounting Surface To Terminal End Distance
1.922 inches nominal
-
Storage Type
general purpose warehouse
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location and 24.0 dc single location
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location
-
Manual Actuator Type And Quantity
1 push button
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum single location
-
Nominal Thread Size
0.375 inches
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Center To Center Distance Between Terminals Parallel To Length
0.500 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18.0 ac single location and 18.0 dc single location
-
Thread Quantity Per Inch
27
-
Pole Quantity
1
-
Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 200 pct single location and 45.000 maximum at 200 pct single location
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
0.765 inches maximum
-
Inclosure Protection Type For Which Designed
general purpose
-
Terminal Type And Quantity
2 quick disconnect, male
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Frequency In Hertz
60.0 single location
-
Body Width
0.460 inches maximum
-
Bushing Length
0.393 inches nominal
-
Thread Series Designator
uns
-
Case Material
plastic
-
End Item Identification
support equipment, f-15; aircraft, f-15