207350

Circuit Breakers

CIRCUIT BREAKER

207350

5925-00-592-0990

5925 - Circuit Breakers

International Business Machines Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.530 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    12a single pole type

  • Body Width

    0.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.050 inches minimum and 2.070 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.840 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    60.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.040 minimum at 150 pct and 30.000 maximum at 150 pct single location

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Terminal Type

    knife blade

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...