82-344-001
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
82-344-001
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
5.000 inches nominal
-
Body Length
3.000 inches nominal
-
Unthreaded Mounting Hole Diameter
0.219 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 4th radio interference
-
Operating Current Rating Per Function In Amps
1.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
1.0 4th radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
4 wire lead input and 4 wire lead output and 1 threaded stud ground
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 1st radio interference
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 3rd radio interference
-
Operating Voltage Rating And Type Per Function
130.0 volts ac 4th radio interference
-
Body Material
metal
-
Style Designator
30 rectangular terminal/terminals on opposite surfaces
-
Overall Height
2.000 inches nominal
-
Body Width
3.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.000 inches nominal
-
Operating Temp Range
-55.0 to 85.0 deg celsius
-
Average Life Rating In Hours
10000.0
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
440.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
1.0 1st radio interference
-
Operating Current Rating Per Function In Amps
1.0 2nd radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
2.4 volts ac 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference