956463

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

956463

5915-00-593-8208

5915 - Filters and Networks

Navair And Navsea Managed

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    6 wire lead input 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Body Length

    5.000 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 2nd radio interference

  • Body Surface Treatment

    tin

  • Maximum Voltage Drop Per Function

    1.0 volts ac 5th radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 6th radio interference

  • Operating Current Rating Per Function In Amps

    3.0 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.500 inches nominal

  • Operating Current Rating Per Function In Amps

    3.0 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 2nd radio interference 2nd function

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 3rd radio interference 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 4th radio interference 4th function

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    3.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 5th radio interference 5th function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Current Rating Per Function In Amps

    3.0 4th radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Operating Current Rating Per Function In Amps

    3.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    3.0 6th radio interference

  • Overall Length

    7.000 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Unthreaded Mounting Hole Diameter

    0.170 inches nominal

  • Body Height

    2.000 inches nominal

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    6.000 inches nominal

  • Maximum Voltage Drop Per Function

    1.0 volts ac 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    6 unthreaded hole

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    24.0 volts ac 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Body Width

    4.000 inches maximum

  • Functional Terminal Type And Quantity

    6 threaded stud output 2nd function

  • Maximum Voltage Drop Per Function

    1.0 volts ac 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.0 volts ac 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...