Q0315

Circuit Breakers

CIRCUIT BREAKER

Q0315

5925-00-606-6529

5925 - Circuit Breakers

Square D Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance re

  • Body Height

    2.580 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 terminal

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Terminal Type And Quantity

    3 clip and 3 compression

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Body Length

    3.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Body Width

    2.230 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Specification/Standard Data

    81348-w-c-375/3 government specification

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...