150A749H01
Coils and Transformers
TRANSFORMER,POWER
150A749H01
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
400.0 hertz nominal single component
-
Body Height
2.187 inches nominal
-
Mounting Facility Quantity
2 single group
-
Winding Function And Quantity
1 primary and 2 secondary single component
-
Winding Operating Current
2.1 amperes ac maximum single component 1st secondary
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary
-
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component 2nd secondary
-
Terminal Type And Quantity
8 tab, solder lug
-
Distance Between Mounting Facility Centers
1.250 inches nominal single mounting facility single center group
-
Inclosure Type
open
-
Mounting Method
flange and slot single group
-
Winding Tap Location
center tap single component all secondary
-
Winding Operating Current
4.95 amperes ac maximum single component 2nd secondary
-
Reliability Indicator
not established
-
Mounting Slot Width
0.156 inches nominal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Body Length
2.218 inches nominal
-
Body Width
2.250 inches nominal