31356
Coils and Transformers
TRANSFORMER,POWER
31356
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Maximum Operating Temp
65.0 deg celsius
-
Body Width
4.375 inches maximum
-
Winding Operating Current
6.7 amperes ac maximum single component 1st secondary
-
Winding Operating Voltage
6.50 ac volts nominal single component all secondary
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Current
24.5 amperes ac maximum single component 4th secondary
-
Body Height
4.125 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.250 inches nominal single mounting facility single center group
-
Winding Operating Current
2.0 amperes ac maximum single component 2nd secondary
-
Winding Operating Current
6.2 amperes ac maximum single component 3rd secondary
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Body Length
4.625 inches maximum
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
5.500 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Frequency Rating
60.0 hertz nominal single component
-
Terminal Type And Quantity
14 tab, solder lug
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Inclosure Type
hermetically sealed
-
Mounting Hole Diameter
0.234 inches nominal single group