70-761EMG3-5A115VAC400-15

Circuit Breakers

CIRCUIT BREAKER

70-761EMG3-5A115VAC400-15

5925-00-617-2018

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.875 inches minimum and 1.999 inches maximum

  • Precious Material And Location

    terminal and contact surfaces silver

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.505 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.998 inches minimum and 2.126 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 9.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Body Width

    0.686 inches minimum and 0.814 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Body Length

    2.436 inches minimum and 2.564 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Boss Height

    0.061 inches minimum and 0.189 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...