P70AB2
Switches
SWITCH,PRESSURE
P70AB2
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Stimulus Rating
35.00 actuation point nominal pounds per square inch and 10.00 differential point nominal pounds per square inch
-
Thread Class
3b single pressure connection
-
Contact Adjustability
deactuation point adjustable, preset and actuation point adjustable, preset
-
Style Designator
rectangular
-
Media For Which Designed
gas or liquid
-
Contact Adjustment Range
+20.00/+50.00 actuation point pounds per square inch and +10.00/+70.00 deactuation point pounds per square inch
-
Contact Load Current Rating
6.9 amperes resistive load first voltage
-
Pressure Switch Type
gage
-
Mounting Method
bracket
-
Thread Series Designator
unc single pressure connection
-
Nonpile-Up Contact Arrangement
1 pole, single throw, both positions maintained
-
Overall Height
5.391 inches nominal
-
Nominal Thread Size
0.250 inches single pressure connection
-
Overall Width
2.031 inches nominal
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
230.0 ac at sea level first voltage
-
Contact Voltage Rating In Volts
115.0 dc at sea level second voltage
-
Overall Length
3.938 inches nominal
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
Terminal Type
tab w/screw
-
Pressure Connector Type
inverted flare, threaded internal single connection
-
Inside Diameter
0.250 inches nominal single connection
-
Contact Load Current Rating
13.9 amperes resistive load second voltage
-
Body Length
3.219 inches nominal
-
Frequency In Hertz
60.0 single voltage