Technical Characteristics

  • Test Data Document

    81349-mil-c-17588 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac all locations and 125.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations and 5000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations and 150.0 amperes dc all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Boss Height

    0.312 inches nominal

  • Mounting Surface To Terminal End Distance

    4.625 inches nominal

  • Nominal Thread Size

    0.250 inches

  • Body Length

    5.000 inches nominal

  • Case Material

    plastic

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 nominal all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 125.0 dc

  • Terminal Type And Quantity

    6 threaded stud

  • ~1

    data on certain environmental and performanc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 210.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    1.688 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Switch Location And Position Designation

    external at pole two

  • Specification/Standard Data

    81349-mil-c-17588 government specification

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.750 inches nominal

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Switch Current Rating And Type In Amps

    10.0 ac and 10.0 dc

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Thread Quantity Per Inch

    20

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.625 inches nominal

  • Switch Contact Arrangement

    single pole, single throw, normally closed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...