40088

Switches

SWITCH,PRESSURE

40088

5930-00-621-4524

5930 - Switches

Hydra-Electric Company

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Method

    threaded stud

  • Operating Temp Rating

    -65.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum

  • Sensing Element Burst Pressure

    180.00 pounds per square inch

  • Overall Length

    3.900 inches maximum

  • Style Designator

    cylindrical

  • Err Default

    err default

  • Terminal Type

    connector, receptacle

  • Media For Which Designed

    liquid

  • Body Length

    2.718 inches maximum

  • Distance Between Mounting Facility Centers

    1.250 inches nominal

  • Thread Series Designator

    unf all pressure connection

  • Overall Diameter

    2.375 inches maximum

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally open, momentary action

  • Thread Direction

    right-hand all threaded stud

  • Inside Diameter

    0.438 inches nominal all connections

  • Thread Class

    3a all threaded stud

  • Thread Class

    3b all pressure connection

  • Features Provided

    hermetically sealed case

  • Thread Series Designator

    unf all threaded stud

  • Proof Pressure

    120.00 pounds per square inch

  • Contact Voltage Rating In Volts

    24.0 dc at sea level single voltage

  • Pressure Connector Type

    plain, threaded internal all connections

  • Nominal Thread Size

    0.190 inches all threaded stud

  • Nominal Thread Size

    0.438 inches single pressure connection

  • Contact Load Current Rating

    1.0 amperes resistive load single voltage

  • Pressure Switch Type

    differential

  • Contact Stimulus Rating

    8.00 actuation point nominal pounds per square inch and 7.00 deactuation point nominal pounds per square inch and 1.00 differential point nominal pounds per square inch

  • Contact Action Stimulus

    decrease

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Mounting Facility Pattern

    two position in-line

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...