JL1A2-8-3

Circuit Breakers

CIRCUIT BREAKER

JL1A2-8-3

5925-00-622-0341

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Switch Terminal Type

    tab, solder lug

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.093 inches maximum

  • Actuator Position Designation

    at pole one

  • Body Width

    0.750 inches nominal

  • Body Length

    2.000 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Bushing Length

    0.312 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Unpackaged Unit Weight

    0.156 pounds

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 1.500 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.469 inches

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...