995565-01

Coils and Transformers

TRANSFORMER,POWER

995565-01

5950-00-624-0418

5950 - Coils and Transformers

Ge Aviation Systems Llc

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    3.312 inches nominal

  • Mounting Hole Diameter

    0.375 inches nominal single group

  • Winding Operating Voltage

    120.00 ac volts minimum single component single primary and 140.00 ac volts maximum single component single primary

  • Terminal Type And Quantity

    3 tab, solder lug

  • Inclosure Type

    partially inclosed, half shell

  • Winding Operating Current

    1.0 amperes ac maximum single component single secondary

  • Winding Operating Voltage

    140.00 ac volts nominal single component single secondary

  • Mounting Method

    unthreaded hole single group

  • Reliability Indicator

    not established

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Function And Quantity

    1 primary single component

  • Winding Power Rating

    140.0 volts-amperes single component single secondary

  • Mounting Facility Quantity

    1 single group

  • Body Outside Diameter

    2.375 inches nominal

  • Frequency Rating

    400.0 hertz minimum single component and 800.0 hertz maximum single component

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...