AP1-148-1

Circuit Breakers

CIRCUIT BREAKER

AP1-148-1

5925-00-624-4908

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Test Data Document

    94117-1179008 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Actuator Function

    trip-reset

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    1

  • Case Material

    metal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct all locations and 1.200 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    vibrationproof and shockproof and hermetically sealed

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Thread Series Designator

    unef

  • Bushing Length

    0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...