SMC180210

Circuit Breakers

CIRCUIT BREAKER

SMC180210

5925-00-636-8297

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Circuit Protection Type

    overcurrent second location

  • Trip Release Method

    magnetic-hydraulic first location

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Special Features

    pole three is a switch only

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and 0.994 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Trip Release Method

    magnetic-hydraulic second location

  • Trip Release Characteristic

    time delay second location

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    1 control

  • Internal Trip Release Configuration

    series trip first location

  • Internal Trip Release Configuration

    series trip second location

  • Nominal Thread Size

    0.164 inches

  • Switch Location And Position Designation

    external at pole three

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 1.000 maximum at 200 pct first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 1.000 maximum at 200 pct second location

  • Switch Terminal Type

    threaded stud

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...