TN231200
Circuit Breakers
CIRCUIT BREAKER
TN231200
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-17588 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Specification/Standard Data
81349-mil-c-17588 government specification
-
Switch Terminal Type
tab, solder lug
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Body Width
4.750 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Trip Release Characteristic
instantaneous all locations and time delay all locations
-
Mounting Facility Type And Quantity
2 threaded hole
-
Switch Current Rating And Type In Amps
10.0 ac and 10.0 dc
-
Trip Release Method
thermal-magnetic all locations
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 toggle
-
Thread Quantity Per Inch
20
-
Frequency In Hertz
60.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.250 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Width
1.688 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
3.625 inches nominal
-
Switch Contact Arrangement
single pole, single throw, normally closed
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations and 125.0 dc all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 5000.0 dc all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Boss Height
0.312 inches nominal
-
Mounting Surface To Terminal End Distance
4.625 inches nominal
-
Nominal Thread Size
0.250 inches
-
Body Length
5.000 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
200.0 amperes ac all locations and 200.0 amperes dc all locations
-
Case Material
plastic
-
Ultimate Trip Time Per Pole In Seconds
3600.000 nominal all locations
-
Switch Voltage Rating And Type In Volts
125.0 ac and 125.0 dc
-
Terminal Type And Quantity
6 threaded stud