TR1432
Coils and Transformers
TRANSFORMER,POWER
TR1432
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
flange single group and slot single group
-
Mounting Slot Width
0.218 inches nominal single group
-
Body Length
4.312 inches nominal
-
Winding Operating Current
316.0 milliamperes ac maximum single component all secondary
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches nominal single mounting facility single center group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Body Height
2.938 inches nominal
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Voltage
184.00 ac volts nominal single component single primary and 216.00 ac volts nominal single component single primary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Winding Operating Voltage
250.00 ac volts nominal single component 1st secondary
-
Frequency Rating
380.0 hertz minimum single component and 1.0 kilohertz maximum single component
-
Winding Operating Voltage
383.00 ac volts nominal single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal single mounting facility single center group
-
Inclosure Type
open
-
Body Width
2.688 inches nominal
-
Mounting Facility Quantity
4 single group