N217388-1

Coils and Transformers

TRANSFORMER,POWER

N217388-1

5950-00-646-2012

5950 - Coils and Transformers

Raytheon Company

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reliability Indicator

    not established

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    3.000 inches nominal

  • Winding Shielding Method

    internal shield grounded to inclosure

  • Body Length

    5.380 inches nominal

  • Body Height

    4.990 inches nominal

  • Inclosure Type

    hermetically sealed

  • Winding Tap Location

    tap w/center tap

  • Winding Operating Current

    250.0 milliamperes dc maximum

  • Winding Operating Voltage

    120.00 ac volts nominal

  • Special Features

    case metal material;0.800 in. o/a height of terminals

  • Terminal Type And Quantity

    6 standoff,solder lug

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.750 inches nominal

  • Frequency Rating

    50.0 hertz minimum and 60.0 hertz maximum

  • Input-Output Phase Relationship

    single phase to single phase

  • Body Width

    4.220 inches nominal

  • Mounting Facility Quantity

    4

  • Mounting Method

    threaded hole

  • Winding Function And Quantity

    1 primary and 1 secondary

  • Winding Operating Voltage

    200.00 ac volts nominal and 850.00 ac volts nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...