715900-2
Coils and Transformers
TRANSFORMER,POWER
715900-2
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
5.000 inches nominal
-
Winding Operating Voltage
2.50 ac volts nominal single component 1st secondary
-
Reliability Indicator
not established
-
Body Height
5.500 inches nominal
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
60.0 hertz nominal single component
-
Inclosure Type
hermetically sealed
-
Nominal Thread Size
0.190 inches single group
-
Thread Direction (Non-Core)
err-070
-
Winding Operating Voltage
490.00 ac volts nominal single component 2nd secondary
-
Thread Series Designator
unf single group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Thread Quantity Per Inch
32 single group
-
Mounting Method
threaded stud single group
-
Winding Tap Location (Non-Core)
err-070
-
Body Length
5.125 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
4.312 inches nominal single mounting facility single center group
-
Winding Operating Current
6.0 amperes ac maximum single component 1st secondary
-
Winding Operating Current
300.0 milliamperes ac maximum single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.500 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
10 standoff insulator
-
Winding Operating Voltage
110.00 ac volts nominal single component single primary and 105.00 ac volts nominal single component single primary and 115.00 ac volts nominal single component single primary
-
Mounting Facility Quantity
4 single group