5399
Coils and Transformers
TRANSFORMER,POWER
5399
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
490.00 ac volts nominal single component 1st secondary and 400.00 ac volts nominal single component 1st secondary and 800.00 ac volts nominal single component 1st secondary
-
Cubic Measure (Non-Core)
21.7 cubic inches
-
Inclosure Type
open
-
Winding Operating Current
60.0 milliamperes ac minimum single component 1st secondary and 100.0 milliamperes ac maximum single component 1st secondary
-
Winding Power Rating
198.0 volts-amperes single component all secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.062 inches nominal single mounting facility single center group
-
Frequency Rating
380.0 hertz minimum single component and 1.0 kilohertz maximum single component
-
Winding Operating Voltage
6.30 ac volts nominal single component 4th secondary
-
Winding Tap Location (Non-Core)
err-070
-
Winding Operating Voltage
90.00 ac volts nominal single component 3rd secondary
-
Mounting Method
threaded hole single group
-
Overall Length
2.609 inches maximum
-
Maximum Operating Temp
180.0 deg celsius
-
Overall Width
2.578 inches maximum
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Winding Operating Voltage
840.00 ac volts nominal single component 2nd secondary
-
Reliability Indicator
not established
-
Terminal Type And Quantity
15 tab, solder lug
-
Thread Class (Non-Core)
err-070
-
Winding Operating Current
67.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Current
16.0 milliamperes ac maximum single component 3rd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Current
1.5 amperes ac maximum single component 4th secondary
-
Thread Series Designator
unc single group
-
Nominal Thread Size
0.130 inches single group
-
Overall Height
3.219 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches nominal single mounting facility single center group