K146-54-1
Coils and Transformers
TRANSFORMER,POWER
K146-54-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Class
2a
-
Thread Class
2b
-
Thread Direction
right-hand
-
Input-Output Phase Relationship
single phase to single phase
-
Body Width
2.063 inches maximum
-
Distance Between Mounting Facility Centers
0.750 inches nominal
-
Inclosure Type
hermetically sealed with oil
-
Mounting Method
threaded stud and threaded hole and slot
-
Winding Operating Current
0.7 amperes ac maximum
-
Winding Operating Current
2.2 amperes ac minimum and 5.5 amperes ac maximum
-
Winding Operating Voltage
5.00 ac volts nominal and 6.30 ac volts nominal and 11.30 ac volts nominal
-
Winding Operating Voltage
6.30 ac volts nominal
-
Special Features
1 primary,5 secondaries
-
Thread Series Designator
unc
-
Terminal Type And Quantity
16 tab,solder lug
-
Reliability Indicator
not established
-
Mounting Slot Width
0.344 inches nominal
-
Frequency Rating
380.0 hertz minimum and 1.0 kilohertz maximum
-
Winding Shielding Method
internal shield grounded to inclosure and core and brought out to terminal
-
Body Length
2.781 inches minimum and 2.906 inches maximum
-
Body Height
2.063 inches minimum and 2.125 inches maximum
-
Distance Between Mounting Facility Centers
1.203 inches nominal
-
Mounting Facility Quantity
2
-
Winding Function And Quantity
1 primary and 5 secondary
-
Cubic Measure
12.7 cubic inches
-
Nominal Thread Size
0.138 inches
-
Winding Tap Location
multiple taps w/o center tap
-
Winding Tap Location
tap w/o center tap
-
Winding Operating Current
0.6 amperes ac maximum
-
Winding Operating Current
175.0 milliamperes ac minimum and 3.8 amperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
6.30 ac volts nominal and 26.00 ac volts nominal and 32.30 ac volts nominal