271-1399-1

Switches

SWITCH,PRESSURE

271-1399-1

5930-00-655-1759

5930 - Switches

Raytheon Company

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Stimulus Rating

    4.00 deactuation point minimum pounds per square inch gage and 6.00 actuation point maximum pounds per square inch gage and 2.00 differential point nominal pounds per square inch gage

  • Thread Class

    3b all threaded hole

  • Thread Series Designator

    unc all threaded hole

  • Thread Quantity Per Inch

    27 single pressure connection

  • Longest Horizontal Distance Between Mounting Centers

    1.500 inches nominal

  • Nominal Thread Size

    0.138 inches all threaded hole

  • Longest Vertical Distance Between Mounting Centers

    1.500 inches nominal

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Body Length

    2.000 inches maximum

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Features Provided

    electrical access port

  • Overall Length

    3.480 inches maximum

  • Overall Height

    2.500 inches maximum

  • Pressure Switch Type

    gage

  • Contact Action Stimulus

    decrease

  • Contact Voltage Rating In Volts

    28.0 dc at sea level second voltage

  • Overall Width

    2.500 inches maximum

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Mounting Method

    bracket and threaded hole

  • Pressure Connector Type

    plain, threaded internal single connection

  • Mounting Facility Pattern

    four position rectangular

  • Proof Pressure

    34.00 pounds per square inch gage

  • Terminal Type

    connector, receptacle

  • Operating Temp Rating

    32.0 deg fahrenheit minimum and 122.0 deg fahrenheit maximum

  • Thread Series Designator

    npt single pressure connection

  • Style Designator

    rectangular w/bracket

  • Thread Quantity Per Inch

    32 all threaded hole

  • Contact Load Current Rating

    15.0 amperes resistive load first voltage

  • Contact Load Current Rating

    10.0 amperes resistive load second voltage

  • Nominal Thread Size

    0.125 inches single pressure connection

  • Media For Which Designed

    gas

  • Body Width

    2.000 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...