FA3684C

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

FA3684C

5915-00-656-6976

5915 - Filters and Networks

Filtron Co Inc

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Voltage Drop Per Function

    1.25 volts ac 2nd radio interference and 4.0 volts dc 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 1st radio interference

  • Body Length

    2.600 inches nominal

  • Input Terminal Manufacturer Code

    07639

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Input Terminal Identification

    ms3102a-24-25

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Maximum Voltage Drop Per Function

    1.25 volts ac 6th radio interference and 4.0 volts dc 6th radio interference

  • Maximum Voltage Drop Per Function

    1.25 volts ac 4th radio interference and 4.0 volts dc 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Functional Terminal Type And Quantity

    6 threaded stud output 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    20.0 and 65.0 and 40.0 and 5.0 and 3.0 and 80.0

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 5th radio interference 5th function and 400.0 volts dc 5th radio interference 5th function

  • Body Height

    2.560 inches nominal

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.25 volts ac 5th radio interference and 4.0 volts dc 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Special Features

    six filtered functions

  • Operating Current Rating Per Function In Amps

    10.0 2nd radio interference

  • Features Provided

    nut and washer

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Maximum Dielectric Withstanding Ac Rms Voltage

    250.0 volts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 4th radio interference 4th function and 400.0 volts dc 4th radio interference 4th function

  • Operating Current Rating Per Function In Amps

    10.0 4th radio interference

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 6th radio interference 6th function and 400.0 volts dc 6th radio interference 6th function

  • Operating Current Rating Per Function In Amps

    10.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function

  • Unthreaded Mounting Hole Diameter

    0.241 inches minimum and 0.247 inches maximum

  • Overall Length

    4.810 inches nominal

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Body Width

    2.060 inches nominal

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Specification/Standard Data

    07639-b8485 manufacturers source control

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Maximum Voltage Drop Per Function

    1.25 volts ac 1st radio interference and 4.0 volts dc 1st radio interference

  • Maximum Voltage Drop Per Function

    1.25 volts ac 3rd radio interference and 4.0 volts dc 3rd radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function

  • Maximum Temp Rise

    25.0 deg celsius

  • Full Load Insertion Loss Frequencies In Megahertz

    0.0 and 1.0 and 100.0 and 10.0 and 0.1 and 1000.0

  • Maximum Dielectric Withstanding Dc Voltage

    800.0 volts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...