ET4017

Circuit Breakers

CIRCUIT BREAKER

ET4017

5925-00-660-3813

5925 - Circuit Breakers

Siemens-Allis Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    105.0 all locations

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.594 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    22.000 minimum at 200 pct all locations and 30.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.594 inches nominal

  • Body Length

    6.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    3.000 inches nominal

  • Body Height

    3.594 inches nominal

  • Terminal Type And Quantity

    4 compression

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    20000.0 ac all locations

  • Body Style

    multipole-single actuator type

  • Trip Release Method

    thermal-magnetic all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...