9073238
Circuit Breakers
CIRCUIT BREAKER
9073238
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and 1.046 inches maximum
-
Body Length
3.703 inches minimum and 3.733 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Unpackaged Unit Weight
0.810 pounds
-
Manual Actuator Type And Quantity
3 toggle
-
Mounting Surface To Terminal End Distance
2.594 inches minimum and 2.624 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.047 inches minimum and 3.077 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Boss Height
0.151 inches minimum and 0.161 inches maximum
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.735 inches minimum and 2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Body Width
3.016 inches minimum and 3.046 inches maximum
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Test Data Document
18876-9169283 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and 1.046 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Ultimate Trip Time Per Pole In Seconds
70.000 minimum all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Operating Voltage Type And Rating Per Pole In Volts
416.0 ac all locations
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations