1654896
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
1654896
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
2.786 inches nominal
-
Undercut Diameter
2.820 inches minimum and 2.825 inches maximum
-
Maximum Starting Torque
5.00 inch-ounces
-
Section Quantity
3
-
Power Dissipation Rating Per Section In Watts
5.0 free air single section
-
Maximum Running Torque
3.70 inch-ounces
-
Pilot Diameter
2.8740 inches minimum and 2.8750 inches maximum
-
Resistance Tolerance Per Section In Percent
-3.0/+3.0 1st section
-
Shaft Length
0.594 inches minimum and 0.656 inches maximum
-
Resistance Tolerance Per Section In Percent
-3.0/+3.0 2nd section
-
Resistance Tolerance Per Section In Percent
-3.0/+3.0 3rd section
-
Shaft Style
round
-
Terminal Type And Quantity
18 turret
-
Overall Diameter
3.512 inches maximum
-
Undercut Width
0.0730 inches minimum and 0.0780 inches maximum
-
Body Style
cylindrical servo mounted
-
Function Conformity Per Section
single section terminal base linearity
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
40.0 single section
-
Electrical Resistance Per Section
20.000 percent, rated amperes c and better finish
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Electrical Resistance Per Section
20.000 percent, rated amperes c and better industrial clears
-
Body Length
2.140 inches minimum and 2.177 inches maximum
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Function Characteristic Per Section
single section 360 deg sine-cosine
-
Actuator Travel Control Feature
continuous motion
-
Body Diameter
2.995 inches minimum and 3.005 inches maximum
-
Electrical Resistance Per Section
20.000 percent, rated amperes c and better select
-
Mounting Method
clamp ring
-
Effective Electrical Rotation In Deg Angular Rotation
360.0 nominal
-
Pilot Length
0.0570 inches minimum and 0.0670 inches maximum
-
Mounting Lip Diameter
2.9950 inches minimum and 3.0050 inches maximum
-
Shaft Diameter
0.249 inches nominal
-
Function Conformity Tolerance Per Section
-1.00/+1.00 single section
-
Terminal Location
radially positioned over more than half the circumference
-
Mounting Lip Depth
0.0880 inches minimum and 0.0980 inches maximum
-
Shaft Runout
0.002 inches