CLM-50
Circuit Breakers
CIRCUIT BREAKER
CLM-50
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
3.156 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
1.062 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
875.0 dc single location
-
Trip Release Method
thermal single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip single location
-
Terminal Type And Quantity
2 screw
-
Body Style
17a single pole type
-
Body Width
1.875 inches nominal
-
Case Material
plastic
-
Unthreaded Mounting Hole Diameter
0.250 inches nominal
-
Mounting Surface To Terminal End Distance
any acceptable
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location
-
Circuit Protection Type
overcurrent single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push button
-
Actuator Position Designation
at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
moisture resistant
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location