72-125-5MG6
Circuit Breakers
CIRCUIT BREAKER
72-125-5MG6
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.047 inches minimum and 2.077 inches maximum
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Continuous Load Current Rating Per Pole
400.0 milliamperes ac all locations and 400.0 milliamperes dc all locations
-
Thread Quantity Per Inch
32
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Contact Arrangement
single pole, double throw
-
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Unpackaged Unit Weight
0.875 pounds
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
-
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 2000.0 dc all locations
-
Mounting Facility Type And Quantity
6 threaded hole
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations
-
Mounting Surface To Terminal End Distance
2.650 inches minimum and 2.800 inches maximum
-
Nominal Thread Size
0.138 inches
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Body Length
2.485 inches minimum and 2.515 inches maximum
-
Frequency In Hertz
60.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Boss Height
0.125 inches minimum and 0.155 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Body Width
2.230 inches minimum and 2.270 inches maximum
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Auxiliary Switch Function And Quantity
1 alarm
-
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant and salt spray proof
-
Manual Actuator Type And Quantity
3 toggle
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud