1837
Coils and Transformers
TRANSFORMER,POWER
1837
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.688 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.312 inches nominal single mounting facility single center group
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Thread Series Designator
unf single group
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Body Width
3.688 inches nominal
-
Reliability Indicator
not established
-
Body Height
5.062 inches nominal
-
Winding Operating Current
125.0 milliamperes ac maximum single component 3rd secondary
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
60.0 hertz nominal single component
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Length
4.312 inches nominal
-
Inclosure Type
hermetically sealed
-
Terminal Type And Quantity
10 solder stud
-
Winding Operating Voltage
300.00 ac volts nominal single component all secondary
-
Nominal Thread Size
0.190 inches single group
-
Winding Operating Voltage
117.00 ac volts nominal single component single primary