AP12-5A

Circuit Breakers

CIRCUIT BREAKER

AP12-5A

5925-00-681-4677

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Trip Release Method

    magnetic-hydraulic all locations

  • Terminal Type And Quantity

    4 wire hook

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 14.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    3.400 ounces

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Pole Quantity

    2

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Time Per Pole In Seconds

    6.500 minimum all locations and 30.000 maximum all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...